ND 1200 T TOOL-CHEK

ND 1202 T

Axes

2 (XZ)

Encoder inputs*

Input frequency

1 VPP or TTL (other interfaces available on request)

1 VPP: 275 kHz; TTL: 3 MHz

Subdivision factor*

10-fold (only for 1 VPP)

Display step1)

Adjustable, max. 7 digits

Linear axis: 1 mm to 0.0001 mm

Angular axis: 1° to 0.0001° (00° 00’ 01”)

Display

5.7” monochrome flat-panel display
for position values, dialogs and inputs, and soft keys

Functions

  • Point measurement with crosshairs
  • 99 tool adapters
  • Memory for 300 tools
  • Counting direction and axis assignment depend on the adapter
  • Radius/diameter switching
  • Entry of tolerances
  • Circle and angle measurement

Error compensation

  • Linear, and segmented linear over up to 30 points
  • Parallelism error

Data interface

  • RS-232-C/V.24
  • USB (type A)

Other connections

Foot switch for two functions, or remote keypad

Accessories

Foot switch, remote keypad, protective cover

Power connection

100 V to 240 V AC (-15 % to +10 %), 47 Hz to 63 Hz, 100 W

Operating temperature

0 °C to 45 °C (storage temperature –20 °C to 70 °C)

Protection EN 60 529

IP 00, front panel IP 40

Mounting*

Tilting base or mounting base

Weight

ND with tilting base:  4.8 kg; ND with mounting adapter:  2 kg

* Please select when ordering

1) Depends on the signal period of the connected encoder as well as the subdivision factor